摘要
A vacuum package based on localized aluminum/silicon-to-glass bonding has been successfully demonstrated. With 3.4 watts heating power, ∼0.2MPa applied contact pressure, and 90 minutes wait time before bonding, vacuum encapsulation at 25mtorr can be achieved. Folded-beam comb drive μ-resonators are encapsulated and used as pressure monitors. Long-term testing of un-annealed vacuum-packaged μ-resonators with a Q of 2500 has demonstrated stable operation after 20 weeks. A μ-resonator with Q of ∼9600 has been vacuum encapsulated and shown to be stable after 7 weeks.
原文 | English |
---|---|
頁面 | 18-21 |
頁數 | 4 |
DOIs | |
出版狀態 | Published - 2001 |
事件 | 14th IEEE International Conference on Micro Electro Mechanical Systems (MEMS 2001) - Interlaken, 瑞士 持續時間: 21 1月 2001 → 25 1月 2001 |