Thulium laser laparoscopic partial nephrectomy without renal hilar control in a porcine model

Thomas Y. Hsueh, Allen W. Chiu*, Andy C. Huang, Chi Wei Lee, Jason Lee, Yi Chin Chang, Shing Hwa Lu

*此作品的通信作者

研究成果: Article同行評審

4 引文 斯高帕斯(Scopus)

摘要

Objective: Laparoscopic partial nephrectomy is a technically challenging procedure. The most important step is to achieve hemostasis during parenchymal resection. We evaluated the feasibility of thulium:yttrium-aluminum-garnet (Th:YAG) laser partial nephrectomy in a porcine model. Materials and Methods: We performed bilateral transperitoneal laparoscopic partial nephrectomies with a 600 μm end-firing laser fiber and a 70 W Th:YAG laser setting in five pigs. Perioperative data including operative time, laser time, estimated blood loss and serum creatinine before and after surgery were collected. Ex vivo retrograde pyelography was performed to detect collecting system leakage after specimen removal. Results: Laser resection and hemostasis were successfully accomplished in all cases, and no perioperative complications occurred. Mean estimated blood loss was 50 mL. Mean laser time was 20 minutes. Mean resected renal mass was 25% of total kidney mass. After 14 and 28 days, exploratory laparotomy found no urinoma formation. Conclusion: Laparoscopic partial nephrectomy using Th:YAG laser is a feasible surgical method in the porcine model. Future clinical application is warranted.

原文English
頁(從 - 到)126-131
頁數6
期刊Urological Science
21
發行號3
DOIs
出版狀態Published - 9月 2010

指紋

深入研究「Thulium laser laparoscopic partial nephrectomy without renal hilar control in a porcine model」主題。共同形成了獨特的指紋。

引用此