T1 - Spontaneous loss versus stimulation gain in pump-probe microscopy
T2 - A proof of concept demonstration
AU - Das, Subir
AU - Rehman, Khalil Ur
AU - Zhuo, Guan Yu
AU - Kao, Fu Jen
N1 - Publisher Copyright:
© The Authors. Published by SPIE under a Creative Commons Attribution 4.0 Unported License.
PY - 2020/3/1
Y1 - 2020/3/1
N2 - The large background, narrow dynamic range, and detector saturation have been the common limiting factors in stimulated emission (SE)-based pump-probe microscopy, attributed to the very small signal overriding the very intense laser probe beam. To better differentiate the signal of interest from the background, lock-in detection is used to measure the fluorescence quenching, which is termed spontaneous loss (SL). The advantages are manifold. The spontaneous fluorescence signal can be well separated from both the pump and the probe beams with filters, thus eliminating the background, enlarging the dynamic range, and avoiding the saturation of the detector. Aim: We propose and demonstrate an integrated pump-probe microscopy technique based on lock-in detection for background removal and dynamic range enhancement through SL detection. Approach: The experimental setup is configured with a pulsed diode laser at a wavelength λpu = 635 nm, acting as a pump (excitation) and a mode-locked Ti:sapphire laser at a central wavelength λpr = 780 nm, serving as the probe beam (stimulation). Both pulse trains are temporally synchronized through high precision delay control by adjusting the length of the triggering cables. The pump and probe beams are alternatively modulated at different frequencies f1 and f2 to extract the stimulated gain (SG) and SL signal. Results: SG signal shows saturation due to the irradiation of the intense probe beam onto the photodetector. However, the detector saturation does not occur at high probe beam power for SL detection. The fluorescence lifetime images are acquired with reduced background. The theoretical signal-to-noise ratios for SG and SL are also estimated by photon statistics. Conclusion: We have confirmed that the detection of SL allows the elimination of the large background without photodetector saturation, which commonly exists in SG configuration. This modality would allow unprecedented manipulation and investigation of fluorophores in fluorescence imaging.
AB - The large background, narrow dynamic range, and detector saturation have been the common limiting factors in stimulated emission (SE)-based pump-probe microscopy, attributed to the very small signal overriding the very intense laser probe beam. To better differentiate the signal of interest from the background, lock-in detection is used to measure the fluorescence quenching, which is termed spontaneous loss (SL). The advantages are manifold. The spontaneous fluorescence signal can be well separated from both the pump and the probe beams with filters, thus eliminating the background, enlarging the dynamic range, and avoiding the saturation of the detector. Aim: We propose and demonstrate an integrated pump-probe microscopy technique based on lock-in detection for background removal and dynamic range enhancement through SL detection. Approach: The experimental setup is configured with a pulsed diode laser at a wavelength λpu = 635 nm, acting as a pump (excitation) and a mode-locked Ti:sapphire laser at a central wavelength λpr = 780 nm, serving as the probe beam (stimulation). Both pulse trains are temporally synchronized through high precision delay control by adjusting the length of the triggering cables. The pump and probe beams are alternatively modulated at different frequencies f1 and f2 to extract the stimulated gain (SG) and SL signal. Results: SG signal shows saturation due to the irradiation of the intense probe beam onto the photodetector. However, the detector saturation does not occur at high probe beam power for SL detection. The fluorescence lifetime images are acquired with reduced background. The theoretical signal-to-noise ratios for SG and SL are also estimated by photon statistics. Conclusion: We have confirmed that the detection of SL allows the elimination of the large background without photodetector saturation, which commonly exists in SG configuration. This modality would allow unprecedented manipulation and investigation of fluorophores in fluorescence imaging.
KW - lock-in detection
KW - nonlinear optics
KW - pump-probe microscopy
KW - spontaneous loss
KW - stimulated emission
UR - http://www.scopus.com/inward/record.url?scp=85082093200&partnerID=8YFLogxK
U2 - 10.1117/1.JBO.25.3.036501
DO - 10.1117/1.JBO.25.3.036501
M3 - Article
C2 - 32170858
AN - SCOPUS:85082093200
SN - 1083-3668
VL - 25
JO - Journal of Biomedical Optics
JF - Journal of Biomedical Optics
IS - 3
M1 - 036501
ER -