Radiofrequency catheter ablation of ventricular arrhythmias originating from the continuum between the aortic sinus of Valsalva and the left ventricular summit: Electrocardiographic characteristics and correlative anatomy

Chin Yu Lin, Fa Po Chung, Yenn Jiang Lin, Eric Chong, Shih Lin Chang, Li Wei Lo, Yu Feng Hu, Ta Chuan Tuan, Tze Fan Chao, Jo Nan Liao, Yao Ting Chang, Yun Yu Chen, Chun Ku Chen, Chuen Wang Chiou, Shih Ann Chen*, Hsuan Ming Tsao

*此作品的通信作者

研究成果: Article同行評審

45 引文 斯高帕斯(Scopus)

摘要

Background Radiofrequency ablation of ventricular arrhythmias (VAs) originating from the continuum between the aortic sinus of Valsalva (ASV) and the left ventricular (LV) summit is a challenge. Objectives The objectives of this study were to investigate the electrocardiographic, electrophysiological, and anatomical characteristics of VAs and to develop an algorithm for predicting the successful ablation site. Methods We recruited 66 patients (mean age, 47 ± 15 years; 42 male patients) with symptomatic VAs originating from the continuum between the ASV and the LV summit who underwent radiofrequency ablation. Patients were classified into 4 groups (group 1: ASV, n = 20; group 2: subvalvular region, n = 15; group 3: great cardiac vein/anterior interventricular vein [GCV/AIV], n = 16; group 4: epicardium requiring pericardial access, n = 15). The QRS morphological characteristics of VAs were compared between the 4 groups. Results Electrocardiographic analysis revealed that the aVL/aVR Q-wave ratio is useful in the prediction of successful ablation sites in the ASV, subvalvular area, GCV/AIV, and epicardium requiring pericardial access at cutoff values of ≤1.415, 1.416-1.535, 1.536-1.740, and >1.740, respectively. The aVL/aVR Q-wave ratio was well correlated with the distance between the successful ablation site and the tip of the LV summit. A distance of >18.9 mm and an LV myocardial thickness of >9.1 mm predicted the need for the epicardial or GCV/AIV approaches. There were no major procedural complications. Eight patients (12.1%) developed VA recurrence during a mean follow-up of 15.9 months (interquartile range 9.2-24.2 months). Conclusion The aVL/aVR Q-wave ratio is a useful parameter for predicting the successful ablation sites of VAs originating from the continuum between the ASV and the LV summit.

原文English
頁(從 - 到)111-121
頁數11
期刊Heart Rhythm
13
發行號1
DOIs
出版狀態Published - 1 1月 2016

指紋

深入研究「Radiofrequency catheter ablation of ventricular arrhythmias originating from the continuum between the aortic sinus of Valsalva and the left ventricular summit: Electrocardiographic characteristics and correlative anatomy」主題。共同形成了獨特的指紋。

引用此