TY - JOUR
T1 - Polychromatic sinogram based material decomposition and reconstruction methods
T2 - integrate standard reference database with an in-house cone-beam micro-computed tomography system
AU - Jin, Shih Chun
AU - Li, Wei Lin
AU - Shen, Chieh
AU - Chen, Jyh Cheng
N1 - Publisher Copyright:
© 2026 The Author(s). Published by IOP Publishing Ltd. Original content from this work may be used under the terms of the https://creativecommons.org/licenses/by/4.0/. Any further distribution of this work must maintain attribution to the author(s) and the title of the work, journal citation and DOI.
PY - 2026/6
Y1 - 2026/6
N2 - This study develops a sinogram-based material decomposition (MD) framework for a dual-energy cone-beam micro-computed tomography (micro-CT) system, providing quantitative spectral imaging without specialized photon-counting detectors. This work aims to address challenges in material characterization, particularly for preclinical in-vivo imaging. The methodology involves acquiring dual-energy projections (50 and 80 kVp) of a standardized reference phantom to calibrate a three-material known basis model. This calibration is performed in the image domain to ensure empirical accuracy, while the decomposition model is solved in the sinogram domain using a robust and computationally efficient Moore–Penrose pseudoinverse solver. By applying mass attenuation coefficients from a standard reference database to these basis maps, the framework synthesizes artifact-reduced virtual monochromatic images, photoelectric effect images (PEIs), and Compton scatter images (CSIs). Our results demonstrate that the framework, once calibrated, is highly generalizable and can be reliably applied to other phantoms and complex in-vivo rat scans. The method achieved accurate, automated segmentation of skeletal structures from soft tissues in in-vivo data, which was quantitatively validated on phantoms with structural similarity index values approaching 1.0 within the object region. The synthesis successfully separated physical attenuation mechanisms, isolating bone-dominant signals in PEIs and soft-tissue signals in CSIs. In conclusion, this study validates an accessible and robust hybrid MD method that enables quantitative, multi-material analysis on conventional micro-CT systems, offering a practical tool for advanced preclinical research.
AB - This study develops a sinogram-based material decomposition (MD) framework for a dual-energy cone-beam micro-computed tomography (micro-CT) system, providing quantitative spectral imaging without specialized photon-counting detectors. This work aims to address challenges in material characterization, particularly for preclinical in-vivo imaging. The methodology involves acquiring dual-energy projections (50 and 80 kVp) of a standardized reference phantom to calibrate a three-material known basis model. This calibration is performed in the image domain to ensure empirical accuracy, while the decomposition model is solved in the sinogram domain using a robust and computationally efficient Moore–Penrose pseudoinverse solver. By applying mass attenuation coefficients from a standard reference database to these basis maps, the framework synthesizes artifact-reduced virtual monochromatic images, photoelectric effect images (PEIs), and Compton scatter images (CSIs). Our results demonstrate that the framework, once calibrated, is highly generalizable and can be reliably applied to other phantoms and complex in-vivo rat scans. The method achieved accurate, automated segmentation of skeletal structures from soft tissues in in-vivo data, which was quantitatively validated on phantoms with structural similarity index values approaching 1.0 within the object region. The synthesis successfully separated physical attenuation mechanisms, isolating bone-dominant signals in PEIs and soft-tissue signals in CSIs. In conclusion, this study validates an accessible and robust hybrid MD method that enables quantitative, multi-material analysis on conventional micro-CT systems, offering a practical tool for advanced preclinical research.
KW - Compton scatter images (CSIs)
KW - cone-beam micro-computed tomography (micro-CT)
KW - material decomposition (MD)
KW - photoelectric effect images (PEIs)
KW - virtual monochromatic images (VMIs)
UR - https://www.scopus.com/pages/publications/105040809299
U2 - 10.1088/2057-1976/ae6f16
DO - 10.1088/2057-1976/ae6f16
M3 - Article
C2 - 42150559
AN - SCOPUS:105040809299
SN - 2057-1976
VL - 12
JO - Biomedical Physics and Engineering Express
JF - Biomedical Physics and Engineering Express
IS - 3
M1 - 035052
ER -