跳至主導覽 跳至搜尋 跳過主要內容

Low-dose graphic-processing-unit based limited-angle CT reconstruction algorithm development for a home-designed dual modality micro-FT/CT system

研究成果: Conference contribution › 同行評審

3 引文 斯高帕斯(Scopus)

摘要

Computed tomography (CT) has evolved into an indispensable imaging method in clinical routine for a long time. It gives us high resolution, high contrast and non-invasive tomographic images in a brief scan time. However, their high radiation dose is an important issue to be solved in CT system development. Iterative algorithms can give us better image quality than analytical types and reduce some artifact effectively. However, they are not only time consuming, but also need very large-scale memory size. In this study, we reduce our projection data to <180-degree limited angle reconstruction, which was based on compressive sensing (CS) criteria and total variation (TV) minimization. This is a computer simulation study combined with CPU and graphic processing units (GPUs). We developed a 3D system matrix in which ray-tracing and circular redundancy technique were included. All CT image data were collected by our homemade micro- FT/CT dual modality system and reconstructed by model based post total-variation constrained algebraic reconstruction technique (ART-TV) algorithm, inner total-variation constrained expectation-maximization (TV-EM) and post total-variation constrained expectation- maximization (EM-TV) in transmission types. The reconstruction volume was 216 × 216 × 384 by 4 × 4 binning of the detector size. There is only 90-degree angular sampling range with 1 degree/projection. Some figures of merit (FOMs) such as rootmean- square error (RMSE), universal quality index (UQI) and coefficient of variation (CV) were used to evaluate image quality. Although now the total speed up ratio is about 1.3 × than CPU multi-threading but compare to our previous study, we push our reconstruction scale from simulated 16 ×16 × 16 and 32 × 34 detector size to the size of a realistic scan. Our study demonstrates that statistic reconstruction technique (SRT) with < 180-degree limited angle reconstruction can produce low-dose CT images.

原文English
主出版物標題2013 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2013
發行者Institute of Electrical and Electronics Engineers Inc.
ISBN(列印)9781479905348
DOIs
出版狀態Published - 2013
事件2013 60th IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2013 - Seoul, 韓國
持續時間: 27 10月 2013 → 2 11月 2013

出版系列

名字IEEE Nuclear Science Symposium Conference Record
ISSN(列印)1095-7863

Conference

Conference2013 60th IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2013
國家/地區韓國
城市Seoul
期間27/10/13 → 2/11/13

指紋

深入研究「Low-dose graphic-processing-unit based limited-angle CT reconstruction algorithm development for a home-designed dual modality micro-FT/CT system」主題。共同形成了獨特的指紋。