LC-lens array with light field algorithm for 3D biomedical applications

Yi-Pai Huang*, Po Yuan Hsieh, Amir Hassanfiroozi, Manuel Martinez, Bahram Javidi, Chao Yu Chu, Yun Hsuan, Wen Chun Chu

*此作品的通信作者

研究成果: Conference contribution同行評審

1 引文 斯高帕斯(Scopus)

摘要

In this paper, liquid crystal lens (LC-lens) array was utilized in 3D bio-medical applications including 3D endoscope and light field microscope. Comparing with conventional plastic lens array, which was usually placed in 3D endoscope or light field microscope system to record image disparity, our LC-lens array has higher flexibility of electrically changing its focal length. By using LC-lens array, the working distance and image quality of 3D endoscope and microscope could be enhanced. Furthermore, the 2D/3D switching ability could be achieved if we turn off/on the electrical power on LClens array. In 3D endoscope case, a hexagonal micro LC-lens array with 350um diameter was placed at the front end of a 1mm diameter endoscope. With applying electric field on LC-lens array, the 3D specimen would be recorded as from seven micro-cameras with different disparity. We could calculate 3D construction of specimen with those micro images. In the other hand, if we turn off the electric field on LC-lens array, the conventional high resolution 2D endoscope image would be recorded. In light field microscope case, the LC-lens array was placed in front of the CMOS sensor. The main purpose of LC-lens array is to extend the refocusing distance of light field microscope, which is usually very narrow in focused light field microscope system, by montaging many light field images sequentially focusing on different depth. With adjusting focal length of LC-lens array from 2.4mm to 2.9mm, the refocusing distance was extended from 1mm to 11.3mm. Moreover, we could use a LC wedge to electrically shift the optics axis and increase the resolution of light field.

原文English
主出版物標題Emerging Liquid Crystal Technologies XI
編輯Nelson V. Tabiryan, Hirotsugu Kikuchi, Dick J. Broer, Liang-Chy Chien
發行者SPIE
ISBN(電子)9781510600041
DOIs
出版狀態Published - 2016
事件Emerging Liquid Crystal Technologies XI - San Francisco, 美國
持續時間: 16 2月 201617 2月 2016

出版系列

名字Proceedings of SPIE - The International Society for Optical Engineering
9769
ISSN(列印)0277-786X
ISSN(電子)1996-756X

Conference

ConferenceEmerging Liquid Crystal Technologies XI
國家/地區美國
城市San Francisco
期間16/02/1617/02/16

指紋

深入研究「LC-lens array with light field algorithm for 3D biomedical applications」主題。共同形成了獨特的指紋。

引用此