Large precursor tolerance database search - A simple approach for estimation of the amount of spectra with precursor mass shifts in proteomic data

Rueyhung Roc Weng, Lichieh Julie Chu, Hung Wei Shu, Timothy H. Wu, Mengchieh Claire Chen, Yuwei Chang, Yihsuan Shannon Tsai, Michael C. Wilson, Yeou Guang Tsay, David R. Goodlett, Wailap Victor Ng*

*此作品的通信作者

研究成果: Article同行評審

1 引文 斯高帕斯(Scopus)

摘要

Mass measurement and precursor mass assignment are independent processes in proteomic data acquisition. Due to misassignments to C-13 peak, or for other reasons, extensive precursor mass shifts (i.e., deviations of the measured from calculated precursor neutral masses) in LC-MS/MS data obtained with the high-accuracy LTQ-Orbitrap mass spectrometers have been reported in previous studies. Although computational methods for post-acquisition reassignment to monoisotopic mass have been developed to curate the MS/MS spectra prior to database search, a simpler method for estimating the fraction of spectra with precursor mass shift so as to determine whether the data require curation remains desirable. Here, we provide the evidence that an easy approach, which applies a large precursor tolerance (2.1. Da or higher) in SEQUEST search against a forward and decoy protein sequence database and then filters the data with PeptideProphet peptide identification probability (. p≥. 0.9), could detect most of the MS/MS spectra containing inaccurate precursor masses. Furthermore, through the implementation of artificial mass shifts on 4000 randomly selected MS/MS spectra, which originally had accurate precursor mass assigned by the mass spectrometers, we demonstrated that the accuracy of the precursor mass has almost negligible influence on the efficacy and fidelity of peptide identification. Biological significance: Integral precursor mass shift is a known problem and thus proteomic data should be handled and analyzed properly to avoid losing important protein identification and/or quantification information. A quick and easy approach for estimating the number of MS/MS spectra with inaccurate precursor mass assignments would be helpful for evaluating the performance of the instrument, determining whether the data requires curation prior to database search or should be searched with specific search parameter(s). Here we demonstrated most of the MS/MS spectra with inaccurate mass assignments (integral or non-integral changes) that could be easily identified by database search with large precursor tolerance windows.

原文English
頁(從 - 到)375-384
頁數10
期刊Journal of Proteomics
91
DOIs
出版狀態Published - 8 10月 2013

指紋

深入研究「Large precursor tolerance database search - A simple approach for estimation of the amount of spectra with precursor mass shifts in proteomic data」主題。共同形成了獨特的指紋。

引用此