External temperature sensor assisted a new low power photoplethysmography readout system for accurate measurement of the bio-signs

Rajeev Kumar Pandey, Paul C.-P. Chao*

*此作品的通信作者

研究成果: Article同行評審

8 引文 斯高帕斯(Scopus)

摘要

This study presents an external temperature sensor assisted a new low power, time-interleave, wide dynamic range, and low DC drift photoplethysmography (PPG) signal acquisition system to obtain the accurate measurement of various bio signs in real-time. The designed chip incorporates a 2-bit control programmable transimpedance amplifier (TIA), a high order filter, a 3:8 programmable gain amplifier (PGA) and 2 × 2 organic light-emitting diode (OLED) driver. Temperature sensor is used herein to compensate the adverse effect of low-skin-temperature on the PPG signal quality. The analog front-end circuit is implemented in the integrated chip with chip area of 2008 μm × 1377 μm and fabricated via TSMC T18 process. With the standard 1.8 V, the experimental result shows that the measured current sensing range is 20 nA–100 uA. The measured dynamic range of the designed readout circuit is 80 dB. The estimated signal to noise ratio is 60 dB@1 uA, and the measured input referred noise is 60.2 pA/Hz½. The total power consumption of the designed chip is 31.32 µW (readout) + 1.62 mW (OLED driver@100% duty cycle). The non-invasive PPG sensor is applied to the wrist artery of the 40 healthy subjects for sensing the pulsation of the blood vessel. The experimental results show that for every 1 °C decrease in mean ambient temperature tends to 0.06 beats/min, 0.125 mmHg and 0.063 mmHg increase in hear rate (HR), systolic (SBP) and diastolic (DBP), respectively. Similarly, for every 1 °C increase in mean ambient temperature tends to 0.13 beats/min, 0.601 mmHg and 0.121 mmHg increase in HR, SBP and DBP, respectively. The measured accuracy and standard error for the HR estimation are 96%, and − 0.022 ± 2.589 beats/minute, respectively. The oxygen stauration (SpO2) measurement results shows that the mean absolute percentage error is less than 5%. The resultant errors for the SBP and DBP measurement are − 0.318 ± 5.19 mmHg and − 0.5 ± 1.91 mmHg, respectively.

原文English
頁(從 - 到)2315–2343
頁數29
期刊Microsystem Technologies
27
發行號6
DOIs
出版狀態Published - 6月 2021

指紋

深入研究「External temperature sensor assisted a new low power photoplethysmography readout system for accurate measurement of the bio-signs」主題。共同形成了獨特的指紋。

引用此