T1 - Establishing a protocol for the compatibilities of closed-system transfer devices with multiple chemotherapy drugs under simulated clinical conditions
AU - Chiang, Shao Chin
AU - Shen, Mandy
AU - Lin, Chen Chia
AU - Chang, Hui Ping
N1 - Publisher Copyright:
© 2021 Chiang et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
PY - 2021/9
Y1 - 2021/9
N2 - Closed-system drug transfer devices (CSTDs) are used to prevent occupational exposure to hazardous drugs in health care providers. They are considered Class II medical devices by the US FDA and are cleared but not approved before marketing. While compatibility tests are conducted by CSTD manufacturers, the procuring institution needs to consider performing its own studies before buying these devices. Herein we tested the compatibility of the components of the Needleless® DualGuard CSTD system (vial access clips, vial access spikes, and administration adaptors) with 10 antineoplastic drugs, under simulated clinical conditions, including compounding and administration, and examined drug potency maintenance, plasticizer migration, and device functionality. All drugs maintained potency within 5%. Diisononyl phthalate leakage was observed from the administration adaptors for paclitaxel and concentrated etoposide solution. In addition, white particles were discovered in CSTDs storing busulfan solution and small cracks were observed on devices which stored melphalan. Thus, it was concluded that even in simulated clinical conditions, instead of extreme conditions, there are still concerns regarding the efficacy and safety of CSTD components. The methodology may be used to implement and detect possible interactions between antineoplastic agents and CSTD components before procurement.
AB - Closed-system drug transfer devices (CSTDs) are used to prevent occupational exposure to hazardous drugs in health care providers. They are considered Class II medical devices by the US FDA and are cleared but not approved before marketing. While compatibility tests are conducted by CSTD manufacturers, the procuring institution needs to consider performing its own studies before buying these devices. Herein we tested the compatibility of the components of the Needleless® DualGuard CSTD system (vial access clips, vial access spikes, and administration adaptors) with 10 antineoplastic drugs, under simulated clinical conditions, including compounding and administration, and examined drug potency maintenance, plasticizer migration, and device functionality. All drugs maintained potency within 5%. Diisononyl phthalate leakage was observed from the administration adaptors for paclitaxel and concentrated etoposide solution. In addition, white particles were discovered in CSTDs storing busulfan solution and small cracks were observed on devices which stored melphalan. Thus, it was concluded that even in simulated clinical conditions, instead of extreme conditions, there are still concerns regarding the efficacy and safety of CSTD components. The methodology may be used to implement and detect possible interactions between antineoplastic agents and CSTD components before procurement.
UR - http://www.scopus.com/inward/record.url?scp=85116132085&partnerID=8YFLogxK
U2 - 10.1371/journal.pone.0257873
DO - 10.1371/journal.pone.0257873
M3 - Article
C2 - 34582474
AN - SCOPUS:85116132085
SN - 1932-6203
VL - 16
JO - PLoS ONE
JF - PLoS ONE
IS - 9 September
M1 - e0257873
ER -