Electromagnetic coil/inductance-based nondestructive methods for locating distal screw-holes of an intramedullary interlocking-nail

Tien-Kan Chung, Hou Jen Chu, Tze Hong Wong, Ya Wen Cheng, Wen-Syang Hsu, Meng Shiue Lee

研究成果: Conference contribution同行評審

4 引文 斯高帕斯(Scopus)

摘要

We report an electromagnetic inductance/coil-based non-destructive method to target distal screw-holes in an intramedullary interlocking-nail surgical operation for fixing a long-bone fracture. The method is a radiation-free approach addressing the over-exposure issue of radioactivity caused by the typical X-ray-imaging approach. According to the method, we fabricate a targeting-system consisting of an internal inductance, external coil, guiding-mechanism, and driving/measurement electronics. When a voltage is applied to the internal inductance embedded in one of the distal screw-holes of a nail inserted in a bone, a directional magnetic flux is generated by the internal inductance due to the electromagnetic induction. Subsequently, the directional magnetic flux penetrates the nail and bone. When the external coil outside the bone scans along the axial and angular directions of the nail/bone, different amount of the generated magnetic flux is detected by the coil and consequently corresponding voltage response is induced in the coil due to the electromagnetic induction. In contrast to the magnetic flux generated and detected by the inductance and coil, respectively, we also investigate the reverse physics-behavior of the flux transmission (i.e., flux generated and detected by the coil and inductance) in order to improve the approach. Finally, by correlating the induced-voltage responses with the scanned axial-locations along the nail/bone, correlation curves are plotted. Through analyzing the curves, a criterion for predicting the location of the screw-holes of the nail is established. When compared the predicted location with the actual location of the screw-hole, the maximum targeting error is 2 mm for locating a screw-hole with a diameter of 5 mm. The result shows the targeting-method is accurate, fast, and easy for the surgeons and significantly simplifies the existed interlocking-nail surgical procedures.

原文English
主出版物標題Health Monitoring of Structural and Biological Systems 2013
DOIs
出版狀態Published - 17 4月 2013
事件SPIE Conference on Health Monitoring of Structural and Biological Systems 2013 - San Diego, CA, 美國
持續時間: 11 3月 201314 3月 2013

出版系列

名字Proceedings of SPIE - The International Society for Optical Engineering
8695
ISSN(列印)0277-786X

Conference

ConferenceSPIE Conference on Health Monitoring of Structural and Biological Systems 2013
國家/地區美國
城市San Diego, CA
期間11/03/1314/03/13

指紋

深入研究「Electromagnetic coil/inductance-based nondestructive methods for locating distal screw-holes of an intramedullary interlocking-nail」主題。共同形成了獨特的指紋。

引用此