Effects of integrated intrinsic foot muscle exercise with foot core training device on balance and body composition among community-dwelling adults aged 60 and above

Sheng Lun Kao, Mei Lan Hsiao, Jen Hung Wang, Chen Sheng Chen, Shin Yuan Chen, Yung Jeng Shiau, Chich Haung Yang*

*此作品的通信作者

研究成果: Article同行評審

摘要

Background: Evidence on the effects of plantar intrinsic foot muscle exercise in older adults remains limited. This study aimed to evaluate the effect of an integrated intrinsic foot muscle exercise program with a novel three-dimensional printing foot core training device on balance and body composition in community-dwelling adults aged 60 and above. Methods: A total of 40 participants aged ≥ 60 years were enrolled in this quasi-experimental, single-group, pretest-posttest design; participants were categorized into two groups, those with balance impairment and those without balance impairment. The participants performed a 4-week integrated intrinsic foot muscle exercise program with a three-dimensional printing foot core training device. The short physical performance battery (SPPB) and timed up and go test were employed to evaluate mobility and balance. A foot pressure distribution analysis was conducted to assess static postural control. The appendicular skeletal muscle mass index and fat mass were measured by a segmental body composition monitor with bioelectrical impedance analysis. The Wilcoxon signed rank test was used to determine the difference before and after the exercise program. Results: Among the 40 enrolled participants (median age, 78.0 years; female, 80.0%; balance-impaired group, 27.5%), the 95% confidence ellipse area of the center of pressure under the eyes-closed condition was significantly decreased (median pretest: 217.3, interquartile range: 238.4; median posttest: 131.7, interquartile range: 199.5; P = 0.001) after the exercise. Female participants without balance impairment demonstrated a significant increase in appendicular skeletal muscle mass index and a decrease in fat mass. Participants in the balance-impaired group exhibited a significant increase in SPPB. Conclusions: Integrated intrinsic foot muscle exercise with a three-dimensional printing foot core training device may improve balance and body composition in adults aged 60 and above. Trial registration: ClinicalTrials.gov ID: NCT05750888 (retrospectively registered 02/03/2023).

原文English
文章編號403
期刊BMC Geriatrics
24
發行號1
DOIs
出版狀態Published - 12月 2024

指紋

深入研究「Effects of integrated intrinsic foot muscle exercise with foot core training device on balance and body composition among community-dwelling adults aged 60 and above」主題。共同形成了獨特的指紋。

引用此