Calibration strategy of the JUNO experiment

JUNO Collaboration

研究成果: Article同行評審

37 引文 斯高帕斯(Scopus)

摘要

We present the calibration strategy for the 20 kton liquid scintillator central detector of the Jiangmen Underground Neutrino Observatory (JUNO). By utilizing a comprehensive multiple-source and multiple-positional calibration program, in combination with a novel dual calorimetry technique exploiting two independent photosensors and readout systems, we demonstrate that the JUNO central detector can achieve a better than 1% energy linearity and a 3% effective energy resolution, required by the neutrino mass ordering determination.

原文American English
文章編號4
頁數33
期刊Journal of High Energy Physics
發行號3
DOIs
出版狀態Published - 1 3月 2021