TY - JOUR
T1 - Biomechanical assessment of vertebroplasty combined with cement-augmented screw fixation for lumbar burst fractures
T2 - A finite element analysis
AU - Hsieh, Yueh Ying
AU - Kuo, Yi Jie
AU - Chen, Chia Hsien
AU - Wu, Lien Chen
AU - Chiang, Chang Jung
AU - Lin, Chun Li
N1 - Publisher Copyright:
© 2020 by the authors.
PY - 2020/3/1
Y1 - 2020/3/1
N2 - A hybrid fixation method, using a combination of vertebroplasty and cement-augmented screws, has been demonstrated as a useful technique for securing osteoporotic burst fractures. The purpose of this study was to assess changes in the range of motion (ROM) and stress in the spine after treating a lumbar burst fracture with this hybrid method. Five finite element models were developed: (a) intact lumbar spine (INT), (b) INT with vertebroplasty at L3 (AwC), (c) two-segment fixation of AwC (AwC-TSF), (d) AwC-TSF model with cement-augmented screws (AwC-TSF-S), and (e) INT with an L3 burst fracture treated with two-segment fixation (TSF). After loading, the models were evaluated in terms of the ROM of each motion segment, stiffness of fusion segments, and stresses on the endplates and screws. The results showed that the TSF model has a larger ROM at the instrumented segments than both the AwC-TSF and AwC-TSF-S models. The stiffness at L2-L4 under extension and lateral bending in AwC-TSF, AwC-TSF-S and TSF was approximately nine times greater than the INT model. In conclusion, the hybrid fixation method (AwC-TSF-S) results in a stiffer construct and lower ROM at instrumented segments, which may also reduce the risk of fracture of adjacent vertebrae.
AB - A hybrid fixation method, using a combination of vertebroplasty and cement-augmented screws, has been demonstrated as a useful technique for securing osteoporotic burst fractures. The purpose of this study was to assess changes in the range of motion (ROM) and stress in the spine after treating a lumbar burst fracture with this hybrid method. Five finite element models were developed: (a) intact lumbar spine (INT), (b) INT with vertebroplasty at L3 (AwC), (c) two-segment fixation of AwC (AwC-TSF), (d) AwC-TSF model with cement-augmented screws (AwC-TSF-S), and (e) INT with an L3 burst fracture treated with two-segment fixation (TSF). After loading, the models were evaluated in terms of the ROM of each motion segment, stiffness of fusion segments, and stresses on the endplates and screws. The results showed that the TSF model has a larger ROM at the instrumented segments than both the AwC-TSF and AwC-TSF-S models. The stiffness at L2-L4 under extension and lateral bending in AwC-TSF, AwC-TSF-S and TSF was approximately nine times greater than the INT model. In conclusion, the hybrid fixation method (AwC-TSF-S) results in a stiffer construct and lower ROM at instrumented segments, which may also reduce the risk of fracture of adjacent vertebrae.
KW - Cement-augmented screws
KW - Finite element analysis
KW - Lumbar burst fractures
KW - Two-segment fixation
KW - Vertebroplasty
UR - http://www.scopus.com/inward/record.url?scp=85082716864&partnerID=8YFLogxK
U2 - 10.3390/app10062133
DO - 10.3390/app10062133
M3 - Article
AN - SCOPUS:85082716864
SN - 2076-3417
VL - 10
JO - Applied Sciences (Switzerland)
JF - Applied Sciences (Switzerland)
IS - 6
M1 - 2133
ER -