A Modified Tip-to-Base LAMPOON to Prevent Left Ventricular Outflow Tract Obstruction in Valve-in-Ring or Valve-in-Valve Transcatheter Mitral Valve Replacement

Huan Chiu Lin, Yung Tsai Lee, Tien Ping Tsao, Kuo Chen Lee, Ming Chon Hsiung, Wei Hsian Yin*, Jeng Wei

*此作品的通信作者

研究成果: Article同行評審

摘要

Background: The Laceration of the Anterior Mitral leaflet to Prevent Outflow ObtructioN (LAMPOON) procedure may be performed from the leaflet tip to base to prevent left ventricular outflow tract obstruction (LVOTO) in patients with high-risk anatomy undergoing valve-in-valve (VIV) or valve-in-(complete)-ring (VIR) transcatheter mitral valve replacement (TMVR). Methods and Results: Thirteen consecutive patients (6 females, average age 67.7 years) with a mean left ventricular ejection fraction of 60%, a median STS score of 3.2%, and degenerative surgical mitral bioprosthesis or ring were treated with a combined, single-stage procedure of preventive LAMPOON and trans-septal TMVR with SAPIEN 3 valves (Edwards Lifesciences, Irvine, CA). Under real-time 3-dimensional transesophageal echocardiography (RT 3D-TEE) guidance, we included the rendezvous technique in the LAMPOON procedure, and all 13 patients were successfully treated by tip-to-base LAMPOON and TMVR. The use of a modified LAMPOON procedure, aided by a rendezvous technique and guided by RT 3D-TEE imaging, offers precise guidance for positioning and aligning the guidewire. This approach not only reduces the need for fluoroscopy and shortens procedure times, but also significantly increases the likelihood of a successful outcome. Importantly, none of the patients in our study experienced unintentional aortic or aortic valve injuries, nor did they develop significant LVOTO following TMVR. In 11 of the 13 (85%) patients, we used a transcatheter SENTINEL™ cerebral protection device (Boston Scientific, Marlborough, MA) for stroke prevention and capture of debris ≥ 2 mm were detected in 8/11 (73%) of the cases. Conclusions: Utilizing intra-operative RT 3D-TEE in conjunction with the rendezvous technique can make the tip-to-base LAMPOON procedure even safer and more effective for patients undergoing VIV or VIR TMVR. Our study also suggests that cerebral protection is indicated in patients undergoing TMVR.

原文English
頁(從 - 到)331-339
頁數9
期刊Acta Cardiologica Sinica
40
發行號3
DOIs
出版狀態Published - 5月 2024

指紋

深入研究「A Modified Tip-to-Base LAMPOON to Prevent Left Ventricular Outflow Tract Obstruction in Valve-in-Ring or Valve-in-Valve Transcatheter Mitral Valve Replacement」主題。共同形成了獨特的指紋。

引用此