TY - JOUR
T1 - 3D laser-printed porous Ti6Al4V dental implants for compromised bone support
AU - Chang Tu, Che
AU - Tsai, Pei I.
AU - Chen, San Yuan
AU - Kuo, Mark Yen Ping
AU - Sun, Jui Sheng
AU - Chang, Jenny Zwei Chieng
PY - 2020/1
Y1 - 2020/1
N2 - Background/Purpose: Alveolar bone loss following peri-implantitis remains a clinical challenge. We aimed to design a novel bioactive dental implant to accommodate the large bone defect caused by removal of previously failed implant. Methods: Bio-ActiveITRI dental implant was manufactured with laser-sintered additive 3D printing technique. A 7.5 mm diameter × 7.0 mm depth osteotomy defect was created at the lateral aspect of distal femur of 20 New Zealand white rabbits to simulate the bony defect after removal of failed dental implant. One side of distal femurs was randomly selected for the commercially pure titanium NobelActive™ implant (control group) and the other side with Bio-ActiveITRI Ti6Al4V porous dental implant (ITRI group). Animals were sacrificed at 4, 8 and 12 weeks after the implants' insertion. The samples were processed for gross morphological analysis, radiographic examination, micro-CT evaluation, and mechanical testing. Results: In histomorphometrical evaluation and micro-CT analysis, active new bone formation and good osseointegration within the ITRI implants were observed at the bone gap surrounding the dental implants. The biomechanical parameters in the Bio-ActiveITRI dental implants were significantly higher than those of the commercially control samples. For the Bio-ActiveITRI dental implants, the trabecular thickness decreased, while the trabecular separation and total porosity increased from the prescribed 1-month to 3-month time points; reflecting the natural remodeling of surrounding bony tissue in the Bio-ActiveITRI dental implants. Conclusion: The novel porous structured Bio-ActiveITRI dental implants may have a great potential for the prosthetic reconstruction where bone support is compromised after removal of a previously failed implant.
AB - Background/Purpose: Alveolar bone loss following peri-implantitis remains a clinical challenge. We aimed to design a novel bioactive dental implant to accommodate the large bone defect caused by removal of previously failed implant. Methods: Bio-ActiveITRI dental implant was manufactured with laser-sintered additive 3D printing technique. A 7.5 mm diameter × 7.0 mm depth osteotomy defect was created at the lateral aspect of distal femur of 20 New Zealand white rabbits to simulate the bony defect after removal of failed dental implant. One side of distal femurs was randomly selected for the commercially pure titanium NobelActive™ implant (control group) and the other side with Bio-ActiveITRI Ti6Al4V porous dental implant (ITRI group). Animals were sacrificed at 4, 8 and 12 weeks after the implants' insertion. The samples were processed for gross morphological analysis, radiographic examination, micro-CT evaluation, and mechanical testing. Results: In histomorphometrical evaluation and micro-CT analysis, active new bone formation and good osseointegration within the ITRI implants were observed at the bone gap surrounding the dental implants. The biomechanical parameters in the Bio-ActiveITRI dental implants were significantly higher than those of the commercially control samples. For the Bio-ActiveITRI dental implants, the trabecular thickness decreased, while the trabecular separation and total porosity increased from the prescribed 1-month to 3-month time points; reflecting the natural remodeling of surrounding bony tissue in the Bio-ActiveITRI dental implants. Conclusion: The novel porous structured Bio-ActiveITRI dental implants may have a great potential for the prosthetic reconstruction where bone support is compromised after removal of a previously failed implant.
KW - Bio-Active dental implant
KW - Bone defect
KW - Laser-sintered additive 3D printing
UR - http://www.scopus.com/inward/record.url?scp=85070105523&partnerID=8YFLogxK
U2 - 10.1016/j.jfma.2019.07.023
DO - 10.1016/j.jfma.2019.07.023
M3 - Article
C2 - 31387841
AN - SCOPUS:85070105523
SN - 0929-6646
JO - Journal of the Formosan Medical Association
JF - Journal of the Formosan Medical Association
ER -