TY - JOUR
T1 - Three-dimensional semiquantitative analysis of gastric emptying SPECT
AU - Kuan, Tzu Wei
AU - Shen, Chih Chieh
AU - Chen, Jyh Cheng
AU - Tu, Kao Yin
AU - Tsao, Chin Ho
AU - Chen, Tzu Hsuan
N1 - Publisher Copyright:
© 2022 Lippincott Williams and Wilkins. All rights reserved.
PY - 2022/1/1
Y1 - 2022/1/1
N2 - Objective We used dynamic single-photon emission computed tomography (D-SPECT) to overcome the interference of the planar dynamic imaging due to the overlap of internal organs, thus more accurate physiological function can be obtained. Methods 3D printed gastric phantom was used to simulate gastric emptying (GE). First, the planar dynamic liquid GE procedure was used and served as the reference value; second, D-SPECT followed by repeated liquid GE procedures with three gamma cameras were used. The emptying flow rate of the gastric phantom simulated three flow rates of liquid, semisolid and solid. Third, we simulated the intestinal activity that interfered with the residual value obtained by 2D dynamic imaging, which was compared with D-SPECT. Then, we brought the 3D VOI data into the postprocessing program to obtain the residual activity curve and residual percentage. Results The residual amount obtained in the phantom at 60th minutes in the first stage is 14.57%; the residual amount of liquid emptying are Siemens: 3.33%, GE: 15.06%, PHILIPS: 1.12%; residual amount for semisolid are Siemens: 47.36%, GE: 54.25%, PHILIPS: 51.57%; residual amount for solids are Siemens: 63.98%, GE: 66.88%, PHILIPS: 63.76%. All values are within the normal range. Then, we simulated the intestinal activity that interfered with the residual value obtained by 2D dynamic imaging: 75-90 min: 10.42, 19.48, 19.51 and 11.02%; however, the residual values obtained with 3D SPECT VOI data: 75-90 min: 1.42, 1.41, 1.35 and 1.02%. These results show that the emptying data errors caused by intestinal overlap can be effectively corrected (P = 0.017). Conclusion D-SPECT imaging can overcome the interference in the semiquantitative data of residual GE caused in 2D mode.
AB - Objective We used dynamic single-photon emission computed tomography (D-SPECT) to overcome the interference of the planar dynamic imaging due to the overlap of internal organs, thus more accurate physiological function can be obtained. Methods 3D printed gastric phantom was used to simulate gastric emptying (GE). First, the planar dynamic liquid GE procedure was used and served as the reference value; second, D-SPECT followed by repeated liquid GE procedures with three gamma cameras were used. The emptying flow rate of the gastric phantom simulated three flow rates of liquid, semisolid and solid. Third, we simulated the intestinal activity that interfered with the residual value obtained by 2D dynamic imaging, which was compared with D-SPECT. Then, we brought the 3D VOI data into the postprocessing program to obtain the residual activity curve and residual percentage. Results The residual amount obtained in the phantom at 60th minutes in the first stage is 14.57%; the residual amount of liquid emptying are Siemens: 3.33%, GE: 15.06%, PHILIPS: 1.12%; residual amount for semisolid are Siemens: 47.36%, GE: 54.25%, PHILIPS: 51.57%; residual amount for solids are Siemens: 63.98%, GE: 66.88%, PHILIPS: 63.76%. All values are within the normal range. Then, we simulated the intestinal activity that interfered with the residual value obtained by 2D dynamic imaging: 75-90 min: 10.42, 19.48, 19.51 and 11.02%; however, the residual values obtained with 3D SPECT VOI data: 75-90 min: 1.42, 1.41, 1.35 and 1.02%. These results show that the emptying data errors caused by intestinal overlap can be effectively corrected (P = 0.017). Conclusion D-SPECT imaging can overcome the interference in the semiquantitative data of residual GE caused in 2D mode.
KW - dynamic single-photon emission computed tomography
KW - gastric emptying scintigraphy (GES)
KW - semiquantitative analysis
KW - time-activity curve (TAC)
KW - volume of interest (VOI)
UR - http://www.scopus.com/inward/record.url?scp=85121974358&partnerID=8YFLogxK
U2 - 10.1097/MNM.0000000000001486
DO - 10.1097/MNM.0000000000001486
M3 - Article
C2 - 34887367
AN - SCOPUS:85121974358
SN - 0143-3636
VL - 43
SP - 17
EP - 23
JO - Nuclear Medicine Communications
JF - Nuclear Medicine Communications
IS - 1
ER -