Three-dimensional semiquantitative analysis of gastric emptying SPECT

Tzu Wei Kuan, Chih Chieh Shen, Jyh Cheng Chen, Kao Yin Tu, Chin Ho Tsao, Tzu Hsuan Chen

Research output: Contribution to journalArticlepeer-review

Abstract

Objective We used dynamic single-photon emission computed tomography (D-SPECT) to overcome the interference of the planar dynamic imaging due to the overlap of internal organs, thus more accurate physiological function can be obtained. Methods 3D printed gastric phantom was used to simulate gastric emptying (GE). First, the planar dynamic liquid GE procedure was used and served as the reference value; second, D-SPECT followed by repeated liquid GE procedures with three gamma cameras were used. The emptying flow rate of the gastric phantom simulated three flow rates of liquid, semisolid and solid. Third, we simulated the intestinal activity that interfered with the residual value obtained by 2D dynamic imaging, which was compared with D-SPECT. Then, we brought the 3D VOI data into the postprocessing program to obtain the residual activity curve and residual percentage. Results The residual amount obtained in the phantom at 60th minutes in the first stage is 14.57%; the residual amount of liquid emptying are Siemens: 3.33%, GE: 15.06%, PHILIPS: 1.12%; residual amount for semisolid are Siemens: 47.36%, GE: 54.25%, PHILIPS: 51.57%; residual amount for solids are Siemens: 63.98%, GE: 66.88%, PHILIPS: 63.76%. All values are within the normal range. Then, we simulated the intestinal activity that interfered with the residual value obtained by 2D dynamic imaging: 75-90 min: 10.42, 19.48, 19.51 and 11.02%; however, the residual values obtained with 3D SPECT VOI data: 75-90 min: 1.42, 1.41, 1.35 and 1.02%. These results show that the emptying data errors caused by intestinal overlap can be effectively corrected (P = 0.017). Conclusion D-SPECT imaging can overcome the interference in the semiquantitative data of residual GE caused in 2D mode.

Original languageEnglish
Pages (from-to)17-23
Number of pages7
JournalNuclear Medicine Communications
Volume43
Issue number1
DOIs
StatePublished - 1 Jan 2022

Keywords

  • dynamic single-photon emission computed tomography
  • gastric emptying scintigraphy (GES)
  • semiquantitative analysis
  • time-activity curve (TAC)
  • volume of interest (VOI)

Fingerprint

Dive into the research topics of 'Three-dimensional semiquantitative analysis of gastric emptying SPECT'. Together they form a unique fingerprint.

Cite this