TY - JOUR
T1 - Systematic review and meta-analysis on incidence of altered sensation of mandibular implant surgery
AU - Lin, Chia Shu
AU - Wu, Shih Yun
AU - Huang, Hsin Yi
AU - Lai, Yu Lin
N1 - Publisher Copyright:
© 2016 Lin et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
PY - 2016/4
Y1 - 2016/4
N2 - Altered sensation (including paresthesia, dysesthesia and hypoesthesia) after mandibular implant surgery may indicate transient or permanent injury of the inferior alveolar nerve and the mental branch, and considerably lower patients' satisfaction about the therapy. Previous studies have shown a great degree of variability on the incidence of altered sensation. We here reported the incidence of altered sensation after mandibular implant surgery based on a meta-analysis of 26 articles published between 1990.1.1 and 2016.1.1. Study quality and risk of bias was assessed and the studies with a lower score were excluded in the metaanalysis. Data synthesis was performed using the logistic-normal random-effect model. The meta-analyses revealed that the short-term (10 days after implant placement) and longterm (1 year after implant placement) incidence was 13% (95% CI, 6%-25%) and 3% (95% CI, 1%-7%), respectively. (2) For the patients who initially reported altered sensation, 80% (95% CI, 52%-94%) of them would return to normal sensation within 6 months after surgery, and 91% (95% CI, 78%-96%) of them would return to normal sensation one year after surgery. We concluded that dentist-patient communication about the risk of altered sensation is critical to treatment planning, since the short-term incidence of altered sensation is substantial (13%). When a patient reports altered sensation, regular assessment for 6 months would help tracing the changes of symptoms. In terms of long-term follow-up (1 year after surgery), the incidence is much lower (3%) and most patients (91%) would return to normal sensation.
AB - Altered sensation (including paresthesia, dysesthesia and hypoesthesia) after mandibular implant surgery may indicate transient or permanent injury of the inferior alveolar nerve and the mental branch, and considerably lower patients' satisfaction about the therapy. Previous studies have shown a great degree of variability on the incidence of altered sensation. We here reported the incidence of altered sensation after mandibular implant surgery based on a meta-analysis of 26 articles published between 1990.1.1 and 2016.1.1. Study quality and risk of bias was assessed and the studies with a lower score were excluded in the metaanalysis. Data synthesis was performed using the logistic-normal random-effect model. The meta-analyses revealed that the short-term (10 days after implant placement) and longterm (1 year after implant placement) incidence was 13% (95% CI, 6%-25%) and 3% (95% CI, 1%-7%), respectively. (2) For the patients who initially reported altered sensation, 80% (95% CI, 52%-94%) of them would return to normal sensation within 6 months after surgery, and 91% (95% CI, 78%-96%) of them would return to normal sensation one year after surgery. We concluded that dentist-patient communication about the risk of altered sensation is critical to treatment planning, since the short-term incidence of altered sensation is substantial (13%). When a patient reports altered sensation, regular assessment for 6 months would help tracing the changes of symptoms. In terms of long-term follow-up (1 year after surgery), the incidence is much lower (3%) and most patients (91%) would return to normal sensation.
UR - http://www.scopus.com/inward/record.url?scp=84964687970&partnerID=8YFLogxK
U2 - 10.1371/journal.pone.0154082
DO - 10.1371/journal.pone.0154082
M3 - Article
C2 - 27100832
AN - SCOPUS:84964687970
SN - 1932-6203
VL - 11
JO - PLoS ONE
JF - PLoS ONE
IS - 4
M1 - e0154082
ER -