Skip to main navigation Skip to search Skip to main content

Short-term outcomes of transcatheter perimembranous ventricular septal defect closure using the konar-multifunctional occluder: the Taiwanese experience

  • Li Chin Liao
  • , Yun Ching Fu*
  • , Pi Chang Lee
  • , Sheng Ling Jan
  • , Ming Chih Lin
  • , Chieh Mao Chuang
  • , Hui Chih Hung*
  • *Corresponding author for this work

Research output: Contribution to journal › Article › peer-review

1 Scopus citations

Abstract

Introduction: Transcatheter device closure of perimembranous ventricular septal defect (PmVSD) using the Lifetech KONAR-MF ventricular septal defect occluder (MFO) presents a promising and effective alternative to surgical repair. Objectives: This study aims to evaluate the 6-month safety and efficacy of the MFO device for PmVSD closure. Materials and methods: We conducted a retrospective analysis of clinical data from patients who underwent percutaneous PmVSD closure using the MFO device at our institution between December 2021 and June 2024. Safety, procedural and 6-month outcomes were systematically assessed. Results: A total of 115 patients (52.2% male) underwent transcatheter PmVSD closure. The median age was 7.6 years [interquartile range (IQR), 4.0–27.2] and weight 25.6 kg (IQR, 14.2–62.6). Median defect size by angiography was 5.7 mm (IQR, 3.8–8.3) on the left ventricle side and 3.3 mm (IQR, 2.3–4.4) on the right ventricle side. Aortic valve prolapse (AVP) was noted in 114 patients (99.1%), with pre-procedural aortic regurgitation (AR) in 36 (31.3%). Median pulmonary artery pressure was 17 mmHg (IQR, 14–20); 48 (41.7%) had Qp/Qs >1.5. All procedures were successful; 33 (28.7%) used a retrograde approach. Median fluoroscopy time was 22 min (IQR, 15–33). Complete closure was achieved in 51.3% at 1 day, 62.6% at 1 month, 69.6% at 3 months, and 83.5% at 6 months. Transient conduction disturbances (n = 4), hypotension (n = 1), and femoral hematoma (n = 1) were observed. No cases of endocarditis, valve injury, or complete atrioventricular block occurred. Conclusion: Transcatheter closure of PmVSD with the MFO demonstrated safety and efficacy during the 6-month follow-up period. Notably, the majority of defects in this cohort were small in size.

Original languageEnglish
Article number1572812
JournalFrontiers in Cardiovascular Medicine
Volume12
DOIs
StatePublished - 2025

Keywords

  • KONAR-MF occluder
  • congenital heart defect
  • occluder
  • transcatheter closure
  • ventricular septal defect

Fingerprint

Dive into the research topics of 'Short-term outcomes of transcatheter perimembranous ventricular septal defect closure using the konar-multifunctional occluder: the Taiwanese experience'. Together they form a unique fingerprint.

Cite this