T1 - Optimization of sampling conditions to minimize sampling errors of both PM2.5 mass and its semi-volatile inorganic ion concentrations
AU - Le, Thi Cuc
AU - Barhate, Pallavi Gajanan
AU - Zhen, Kai Jing
AU - Mishra, Manisha
AU - Pui, David Y.H.
AU - Tsai, Chuen Jinn
N1 - Publisher Copyright:
© 2023 American Association for Aerosol Research.
PY - 2023
Y1 - 2023
N2 - The accurate measurement of PM2.5 and its inorganic matters (IMs) is crucial for compliance monitoring and understanding particle formation. However, semi-volatile IMs (SVIMs) like NH4+, NO3−, and Cl− tend to evaporate from particles, causing sampling artifacts. The evaporation loss occurs due to many factors making the quantitative prediction difficult. This study aimed to investigate the evaporation loss of SVIMs in PM2.5 under different sampling conditions. In the field tests, when a normal single Teflon filter (STF) sampler, which is like a Federal Reference Method (FRM) sampler, was used to sample PM2.5 at ambient conditions, a significant SVIM evaporation loss was observed, resulting in negative biases for total IMs (−25.68 ± 3.25%) and PM2.5 concentrations (−9.87 ± 4.27%). But if PM2.5 was sampled by a chilled Teflon filter sampler (CTF) at 4 °C following aerosol dehumidification so that relative humidity (RH) was controlled to within the 10–20% range (RHd), evaporation loss was minimized with a bias of < ±10% for both total IMs and PM2.5 based on the reference data. When RHd is below 10%, both IMs and PM2.5 are under-measured, but only PM2.5 is over-measured when RHd is >20%. A model considering predictable saturation ratios for NH4+, NO3−, and Cl− under various pressure drop, temperature and RH conditions was developed to predict accurately the actual concentrations of PM2.5 and its SVIMs for the STF. Additionally, the ISORROPIA-II model predicted SVIMs effectively for the CTF. In summary, using the CTF at optimized sampling conditions can achieve accurate measurement of both SVIMs and PM2.5 concentrations simultaneously.
AB - The accurate measurement of PM2.5 and its inorganic matters (IMs) is crucial for compliance monitoring and understanding particle formation. However, semi-volatile IMs (SVIMs) like NH4+, NO3−, and Cl− tend to evaporate from particles, causing sampling artifacts. The evaporation loss occurs due to many factors making the quantitative prediction difficult. This study aimed to investigate the evaporation loss of SVIMs in PM2.5 under different sampling conditions. In the field tests, when a normal single Teflon filter (STF) sampler, which is like a Federal Reference Method (FRM) sampler, was used to sample PM2.5 at ambient conditions, a significant SVIM evaporation loss was observed, resulting in negative biases for total IMs (−25.68 ± 3.25%) and PM2.5 concentrations (−9.87 ± 4.27%). But if PM2.5 was sampled by a chilled Teflon filter sampler (CTF) at 4 °C following aerosol dehumidification so that relative humidity (RH) was controlled to within the 10–20% range (RHd), evaporation loss was minimized with a bias of < ±10% for both total IMs and PM2.5 based on the reference data. When RHd is below 10%, both IMs and PM2.5 are under-measured, but only PM2.5 is over-measured when RHd is >20%. A model considering predictable saturation ratios for NH4+, NO3−, and Cl− under various pressure drop, temperature and RH conditions was developed to predict accurately the actual concentrations of PM2.5 and its SVIMs for the STF. Additionally, the ISORROPIA-II model predicted SVIMs effectively for the CTF. In summary, using the CTF at optimized sampling conditions can achieve accurate measurement of both SVIMs and PM2.5 concentrations simultaneously.
KW - Kihong Park
UR - http://www.scopus.com/inward/record.url?scp=85174629242&partnerID=8YFLogxK
U2 - 10.1080/02786826.2023.2265454
DO - 10.1080/02786826.2023.2265454
M3 - Article
AN - SCOPUS:85174629242
SN - 0278-6826
VL - 57
SP - 1264
EP - 1279
JO - Aerosol Science and Technology
JF - Aerosol Science and Technology
IS - 12
ER -