Measurement of superfluid He-3 film flow by inter-digitated capacitors

M Saitoh*, H Ikegami, H Mukuda, K Kono

*Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

7 Scopus citations

Abstract

We report the measurements of the critical current of superfluid He-3 film for the thickness of 0.47 mum. By employing inter-digitated capacitors, 2.5x10(-2) mm(3) He-3 can be manipulated with 0.4% resolution. Critical current J(c)(f) of superfluid He-3 film were observed for the onset of dissipative flow. The magnitude of measured J(c)(f) is considerably smaller than the theoretically predicted pair-breaking critical current. This result indicates that another mechanism must participate in the dissipation of superflow.

Original languageEnglish
Pages (from-to)357-362
Number of pages6
JournalJournal of Low Temperature Physics
Volume134
Issue number1-2
DOIs
StatePublished - Jan 2004
Event13th International Symposium on Quantum Fluids and Solids - ALBUQUERQUE
Duration: 3 Aug 20038 Aug 2003

Keywords

  • Magnetic Material
  • Critical Current
  • Film Flow
  • Dissipative Flow

Fingerprint

Dive into the research topics of 'Measurement of superfluid He-3 film flow by inter-digitated capacitors'. Together they form a unique fingerprint.

Cite this