Background The objective of this study was to evaluate the interaction between the length polymorphism of the guanosine thymidine repeat [(GT) n] in the heme oxygenase-1 (HO-1) gene and far-infrared (FIR) therapy on access flow (Qa) and arteriovenous fistula (AVF) patency in hemodialysis (HD) patients. Methods A total of 280 HD patients were randomized into a control group (n = 141) and the FIR group (n = 139) who received 40 min of FIR therapy three times weekly for a year during the study period from May 2005 to December 2007. Access flow was measured during HD. The [(GT)n] was determined with the definition of long (L) allele as [(GT)n] ≥ 30 and short (S) allele as [(GT)n] < 30.ResultsThe Qa decreased from S/S to S/L and further to the L/L group but increased by FIR therapy with the highest Qa increase in the S/S group. The incidence of AVF malfunction decreased both from the L/L, S/L to S/S group (32.4 versus 17.2 versus 10.9%, P = 0.007) and from the control group to FIR group (27.5 versus 12.6%, P = 0.004). Significant associations were found between AVF malfunction and the following factors (hazard ratio, P-value): a past history of AVF malfunction (2.45, P = 0.044), FIR therapy (0.369, P = 0.03) and L/L genotypes of HO-1 (2.531 versus S/S + S/L genotypes). The 1-year unassisted patency decreased from 91.9 and 77.6% in S/S and S/L subgroups with and without FIR therapy to 75.8 and 60% for L/L subgroup with and without FIR therapy, respectively (P < 0.001). Conclusions FIR therapy improves Qa and patency of AVF in HD patients, with the best protective effect in those with S/S genotype of HO-1.

Original languageEnglish
Pages (from-to)1284-1293
Number of pages10
JournalNephrology Dialysis Transplantation
Volume28
Issue number5
DOIs
StatePublished - May 2013

Keywords

  • arteriovenous fistula
  • far-infrared therapy
  • heme oxygenase-1
  • hemodialysis
  • length polymorphism