False Positive Analysis of Functional MRI During Simulated Deep Brain Stimulation

H. L. Liu, Chih-Mao Huang, S. N. Lim, W. C. Kuan, H. M. Chen, T. Wu, Y. Y. Hsu

Research output: Contribution to journalMeeting Abstractpeer-review

Abstract

Purpose: Recent studies showed that MRI can be safely performed on patients with deep brain stimulation (DBS) device in place when the stimulator is turned off. By interleaving the DBS and echo‐planar imaging (EPI) acquisition, functional MRI (fMRI) may be a useful tool for understanding the mechanism of DBS as well as helping the localization of electrodes. This study aimed to investigate the possible false positive activations due to the limited time interval between the end of DBS and the start of EPI acquisition. Method and Materials: The study was performed using a 1.5‐T Philips MRI scanner with a DBS electrode (Medtronic, Minneapolis MN) positioned in the center of a gel‐filled phantom. The experimental run consisted of alternative 5 stimulation‐off and 4 stimulation‐on blocks (the stimulator was turned on for 2 seconds immediately after each readout). The control run consisted of total stimulation‐off blocks. A single‐shot GE EPI (TR/TE = 6000ms/60ms, FOV = 192mm, matrix = 64×64, SW = 3mm) was used, with 10/30 slices per measurement in for long/short inter‐scan waiting times (ISWT). Data were analyzed using SPM2. False activation and deactivation volumes were computed at different statistical thresholds. Results: For both activation and deactivation, no false positive voxels were detected for all conditions at corrected p<0.05 or uncorrected p<0.001. For uncorrected p>0.001, number of false activated/deactivated voxels increased with p‐value increased. No increased trend was observed with the experimental conditions as compared to the control conditions. Similar trends were observed when comparing activation vs. deactivation and long vs. short ISWT. Conclusion: An ISWT of 2230 ms (TR= 6s, 30‐slice acquisition) was found to be sufficient for placing a 2‐s DBS without increased false positive detections of activation/deactivation. A statistical threshold of p<0.001 or tighter is recommended for fMRI involving the similar amount of total voxels as this study.

Original languageEnglish
Pages (from-to)2012-2012
Number of pages1
JournalMedical Physics
Volume33
Issue number6
DOIs
StatePublished - Jun 2006
Event48th Annual Meeting of the American-Association-of-Physicists-in-Medicine - Orlando, United States
Duration: 30 Jul 20063 Aug 2006

Fingerprint

Dive into the research topics of 'False Positive Analysis of Functional MRI During Simulated Deep Brain Stimulation'. Together they form a unique fingerprint.

Cite this