TY - JOUR
T1 - Factors predicting response to the first epidural blood patch in spontaneous intracranial hypotension
AU - Wu, Wei
AU - Hseu, Shu Shya
AU - Fuh, Jong Ling
AU - Lirng, Jiing Feng
AU - Wang, Yen Feng
AU - Chen, Wei Ta
AU - Chen, Shih Pin
AU - Wang, Shuu Jiun
N1 - Publisher Copyright:
© The Author (2016). Published by Oxford University Press on behalf of the Guarantors of Brain. All rights reserved.
PY - 2017/2
Y1 - 2017/2
N2 - Spontaneous intracranial hypotension results from cerebrospinal fluid leakage. Currently, the treatment of choice for spontaneous intracranial hypotension is the epidural blood patch, which has a variable response rate and no clear outcome predictors. This study aimed to identify predictors for response rate of a first targeted epidural blood patch in patients with spontaneous intracranial hypotension. We reviewed cases of patients with spontaneous intracranial hypotension who received targeted epidural blood patch at our hospital between 1 January 2007 and 1 July 2014. The outcome measure was first epidural blood patch response. We analysed demographics, clinical manifestations, neuroimaging findings (non-contrast heavily T2-weighted magnetic resonance myelography and brain magnetic resonance imaging), and blood volume as potential outcome predictors. Significant predictors were tested and a decision tree was used to construct a predictive model. In total, 150 patients with spontaneous intracranial hypotension were included for final analyses. Their overall first targeted epidural blood patch response rate was 58.7%. Among patients with a greater injected blood volume (≥22.5 versus <22.5 ml), the response rate was higher (67.9% versus 47.0%, P = 0.01). In brain and spinal magnetic resonance imaging studies, significant predictors included anterior epidural cerebrospinal fluid collection length (<8 versus ≥8 segments; 72.5% versus 37.3%, odds ratio = 4.4, 95% confidence interval: 2.2-8.9, P < 0.001) and midbrain-pons angle (≥40° versus <40°; 71.3% versus 37.5%, odds ratio = 4.1, 95% confidence interval 2.1-8.3, P < 0.001). Decision tree analyses showed that patients with anterior epidural CSF collection involving <8 segments and an injected blood volume ≥22.5 ml had an 80.0% response rate. Patients with anterior epidural cerebrospinal fluid collection involving ≥8 segments and a midbrain-pons angle <40° had a 21.2% response rate. These three variables predicted first epidural blood patch response in 71.3% of patients. Brain and spinal neuroimaging findings and epidural blood patch blood volume can be used to predict targeted first epidural blood patch response in patients with spontaneous intracranial hypotension.
AB - Spontaneous intracranial hypotension results from cerebrospinal fluid leakage. Currently, the treatment of choice for spontaneous intracranial hypotension is the epidural blood patch, which has a variable response rate and no clear outcome predictors. This study aimed to identify predictors for response rate of a first targeted epidural blood patch in patients with spontaneous intracranial hypotension. We reviewed cases of patients with spontaneous intracranial hypotension who received targeted epidural blood patch at our hospital between 1 January 2007 and 1 July 2014. The outcome measure was first epidural blood patch response. We analysed demographics, clinical manifestations, neuroimaging findings (non-contrast heavily T2-weighted magnetic resonance myelography and brain magnetic resonance imaging), and blood volume as potential outcome predictors. Significant predictors were tested and a decision tree was used to construct a predictive model. In total, 150 patients with spontaneous intracranial hypotension were included for final analyses. Their overall first targeted epidural blood patch response rate was 58.7%. Among patients with a greater injected blood volume (≥22.5 versus <22.5 ml), the response rate was higher (67.9% versus 47.0%, P = 0.01). In brain and spinal magnetic resonance imaging studies, significant predictors included anterior epidural cerebrospinal fluid collection length (<8 versus ≥8 segments; 72.5% versus 37.3%, odds ratio = 4.4, 95% confidence interval: 2.2-8.9, P < 0.001) and midbrain-pons angle (≥40° versus <40°; 71.3% versus 37.5%, odds ratio = 4.1, 95% confidence interval 2.1-8.3, P < 0.001). Decision tree analyses showed that patients with anterior epidural CSF collection involving <8 segments and an injected blood volume ≥22.5 ml had an 80.0% response rate. Patients with anterior epidural cerebrospinal fluid collection involving ≥8 segments and a midbrain-pons angle <40° had a 21.2% response rate. These three variables predicted first epidural blood patch response in 71.3% of patients. Brain and spinal neuroimaging findings and epidural blood patch blood volume can be used to predict targeted first epidural blood patch response in patients with spontaneous intracranial hypotension.
KW - Cerebrospinal fluid (CSF) leakage
KW - Epidural blood patch
KW - Midbrain-pons angle
KW - Spontaneous intracranial hypotension
UR - http://www.scopus.com/inward/record.url?scp=85014750577&partnerID=8YFLogxK
U2 - 10.1093/brain/aww328
DO - 10.1093/brain/aww328
M3 - Article
C2 - 28043956
AN - SCOPUS:85014750577
SN - 0006-8950
VL - 140
SP - 344
EP - 352
JO - Brain
JF - Brain
IS - 2
ER -