TY - JOUR
T1 - Efficient and Adaptive Error Recovery in a Micro-Electrode-Dot-Array Digital Microfluidic Biochip
AU - Li, Zipeng
AU - Lai, Kelvin Yi Tse
AU - McCrone, John
AU - Yu, Po Hsien
AU - Chakrabarty, Krishnendu
AU - Pajic, Miroslav
AU - Ho, Tsung Yi
AU - Lee, Chen-Yi
PY - 2018/3/1
Y1 - 2018/3/1
N2 - A digital microfluidic biochip (DMFB) is an attractive technology platform for automating laboratory procedures in biochemistry. In recent years, DMFBs based on a micro-electrode-dot-array (MEDA) architecture have been proposed. MEDA biochips can provide advantages of better capability of droplet manipulation and real-time sensing ability. However, errors are likely to occur due to defects, chip degradation, and the lack of precision inherent in biochemical experiments. Therefore, an efficient error-recovery strategy is essential to ensure the correctness of assays executed on MEDA biochips. By exploiting MEDA-specific advances in droplet sensing, we present a novel error-recovery technique to dynamically reconfigure the biochip using real-time data provided by on-chip sensors. Local recovery strategies based on probabilistic-timed-automata are presented for various types of errors. An online synthesis technique and a control flow are also proposed to connect local-recovery procedures with global error recovery for the complete bioassay. Moreover, an integer linear programming-based method is also proposed to select the optimal local-recovery time for each operation. Laboratory experiments using a fabricated MEDA chip are used to characterize the outcomes of key droplet operations. The PRISM model checker and three benchmarks are used for an extensive set of simulations. Our results highlight the effectiveness of the proposed error-recovery strategy.
AB - A digital microfluidic biochip (DMFB) is an attractive technology platform for automating laboratory procedures in biochemistry. In recent years, DMFBs based on a micro-electrode-dot-array (MEDA) architecture have been proposed. MEDA biochips can provide advantages of better capability of droplet manipulation and real-time sensing ability. However, errors are likely to occur due to defects, chip degradation, and the lack of precision inherent in biochemical experiments. Therefore, an efficient error-recovery strategy is essential to ensure the correctness of assays executed on MEDA biochips. By exploiting MEDA-specific advances in droplet sensing, we present a novel error-recovery technique to dynamically reconfigure the biochip using real-time data provided by on-chip sensors. Local recovery strategies based on probabilistic-timed-automata are presented for various types of errors. An online synthesis technique and a control flow are also proposed to connect local-recovery procedures with global error recovery for the complete bioassay. Moreover, an integer linear programming-based method is also proposed to select the optimal local-recovery time for each operation. Laboratory experiments using a fabricated MEDA chip are used to characterize the outcomes of key droplet operations. The PRISM model checker and three benchmarks are used for an extensive set of simulations. Our results highlight the effectiveness of the proposed error-recovery strategy.
KW - Digital microfluidics
KW - error recovery
KW - micro-electrode-dot-array (MEDA)
KW - online synthesis
KW - optimization
UR - http://www.scopus.com/inward/record.url?scp=85028943295&partnerID=8YFLogxK
U2 - 10.1109/TCAD.2017.2729347
DO - 10.1109/TCAD.2017.2729347
M3 - Article
AN - SCOPUS:85028943295
SN - 0278-0070
VL - 37
SP - 601
EP - 614
JO - IEEE Transactions on Computer-Aided Design of Integrated Circuits and Systems
JF - IEEE Transactions on Computer-Aided Design of Integrated Circuits and Systems
IS - 3
ER -