T1 - Design and Construction of High-Frequency Cardiac Defibrillator for Small Animals
AU - Chiou, Yu An
AU - Cheng, Li Kuan
AU - Lin, Shien Fong
PY - 2020/7
Y1 - 2020/7
N2 - The main goal of this research is to evaluate the defibrillation efficacy with the high-frequency waveform on ventricular fibrillation in small animals. A biphasic defibrillator with adjustable frequency was designed for this study. This custom-designed defibrillator can be adjusted to generate four different frequencies of 125, 250, 500, and 1000 Hz. Six rat hearts were induced VT/VF by electrical induction using the waveform of these four frequencies. Success VT/VF-induction by applying those four frequencies were recorded and observed by optical mapping. The results showed that the VT/VF-induction success rate is increasing along with higher frequencies. The VT/VF-induction success rate is 16% in 125Hz and 250 Hz, 33% in 500 Hz, and 100% in 1000 Hz with S1-S2 protocol at 100 ms coupling interval. Also, using optical mapping technique, shock-induced optical potential showed that only high-frequency waveform exhibited the largest tissue responses in the middle position of the heart. In conclusion, high-frequency (1000Hz) defibrillation waveform has the highest defibrillation efficacy comparing to other lower frequencies used in this study.
AB - The main goal of this research is to evaluate the defibrillation efficacy with the high-frequency waveform on ventricular fibrillation in small animals. A biphasic defibrillator with adjustable frequency was designed for this study. This custom-designed defibrillator can be adjusted to generate four different frequencies of 125, 250, 500, and 1000 Hz. Six rat hearts were induced VT/VF by electrical induction using the waveform of these four frequencies. Success VT/VF-induction by applying those four frequencies were recorded and observed by optical mapping. The results showed that the VT/VF-induction success rate is increasing along with higher frequencies. The VT/VF-induction success rate is 16% in 125Hz and 250 Hz, 33% in 500 Hz, and 100% in 1000 Hz with S1-S2 protocol at 100 ms coupling interval. Also, using optical mapping technique, shock-induced optical potential showed that only high-frequency waveform exhibited the largest tissue responses in the middle position of the heart. In conclusion, high-frequency (1000Hz) defibrillation waveform has the highest defibrillation efficacy comparing to other lower frequencies used in this study.
KW - Action potential
KW - High-frequency defibrillation
KW - Optical mapping
KW - Ventricular fibrillation
UR - http://www.scopus.com/inward/record.url?scp=85091028663&partnerID=8YFLogxK
U2 - 10.1109/EMBC44109.2020.9175702
DO - 10.1109/EMBC44109.2020.9175702
M3 - Conference contribution
AN - SCOPUS:85091028663
T3 - Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS
SP - 2614
EP - 2617
BT - 42nd Annual International Conferences of the IEEE Engineering in Medicine and Biology Society
PB - Institute of Electrical and Electronics Engineers Inc.
T2 - 42nd Annual International Conferences of the IEEE Engineering in Medicine and Biology Society, EMBC 2020
Y2 - 20 July 2020 through 24 July 2020
ER -