Five cell parameters of a twisted nematic liquid crystal device (TNLCD), namely, cell gap, pretilt angle, twisted angle, rubbing angle, and phase retardation are precisely measured by the developed amplitudesensitive heterodyne polarimeter (ASHP) simultaneously integrated with Yeh and Gu's transfer matrix and Lien's transfer matrix. This proposed method can characterize the five cell parameters under the arrangement of a single wavelength at normal incidence. In contrast to the conventional methods on cell parameter detection either by adopting a multiple wavelength laser beam at normal incidence or by using a single wavelength laser beam under oblique incident to TNLCD, this method presents the advantage of not only having a simple setup but also the possibility to measure simultaneously five cell parameters on the characterization of TNLCD at high speed.

Original languageEnglish
Pages (from-to)8759-8766
Number of pages8
JournalOptics Express
Volume18
Issue number9
DOIs
StatePublished - 26 Apr 2010