A new cuffless optical sensor for blood pressure measuring with self-adaptive signal processing

Yung Hua Kao, Chang-Po Chao, Tse Yi Tu, Keng Yueh Chiang, Chin Long Wey

Research output: Chapter in Book/Report/Conference proceedingConference contributionpeer-review

7 Scopus citations

Abstract

A new cuffless, wireless optical blood pressure (BP) sensor is successfully developed by this study. This device employs the technique of photoplethysmograph (PPG) to read out in real time the intravascular blood volume change and then to calculate BP. The system utilizes a red-light LED with a wavelengths of 660 nm. The readout circuit includes a pre-amplifier, a band-pass filter, a programmable gain amplifier (PGA), an Arduino unit for calculation and a Bluetooth module for wireless communication. A notebook or a mobile phone is also used to display continuous BPs and conducts statistical analysis/results. The passband is from 0.3 to 3.4 Hz. The range of adjustable gain are from 60 to 80 dB. Measured PPGs of different subjects can be auto-adjusted with varied gain by a PGA with a pre-designed digital circuit. In results, the signal-to-noise ratio (SNR) is improved for accurate estimates on BPs. 8 subjects participated in the experimental validation, in which the obtained BPs are compared with the results from a commercial blood pressure monitor by OMRON. The maximum error of experimental results is ± 6 mmHg, which is less than 8 mmHg conforming to the requirement by the Advancement of Medical Instrumentation (AAMI). This study pioneers to report stable, accurate estimates on BPs by a cuffless optical hand-held device.

Original languageEnglish
Title of host publicationIEEE Sensors, SENSORS 2016 - Proceedings
PublisherInstitute of Electrical and Electronics Engineers Inc.
ISBN (Electronic)9781479982875
DOIs
StatePublished - 5 Jan 2017
Event15th IEEE Sensors Conference, SENSORS 2016 - Orlando, United States
Duration: 30 Oct 20162 Nov 2016

Publication series

NameProceedings of IEEE Sensors
ISSN (Print)1930-0395
ISSN (Electronic)2168-9229

Conference

Conference15th IEEE Sensors Conference, SENSORS 2016
Country/TerritoryUnited States
CityOrlando
Period30/10/162/11/16

Keywords

  • diastolic blood pressure (DBP)
  • photoplethysmograph (PPG)
  • systolic blood pressure (SBP)

Fingerprint

Dive into the research topics of 'A new cuffless optical sensor for blood pressure measuring with self-adaptive signal processing'. Together they form a unique fingerprint.

Cite this