A Fully Integrated Asymmetrical Shunt Switched-Capacitor DC-DC Converter with Fast Optimum Ratio Searching Scheme for Load Transient Enhancement

Yen Ting Lin, Yan Jiun Lai, Hung Wei Chen, Wen Hau Yang, Yu Sheng Ma, Ke-Horng Chen*, Ying Hsi Lin, Shian Ru Lin, Tsung Yen Tsai

*Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

13 Scopus citations

Abstract

This paper presents a modified negator-based switched-capacitor (NSC) dc-dc converter to achieve fine-grained voltage conversion ratios. Based on a concept of reconfiguring several 2:1 switched-capacitor (SC) converters in series and parallel at the last stage, the proposed asymmetrical shunt SC (ASSC) converter provides more controllable variables of forward gain and feedback gain to decide different power path interconnections and increase the available conversion ratios, with a little sacrifice of its slow switching limit output impedance. The switching loss of the bottom-plate parasitic capacitance in the ASSC converter is less than the switching loss of the NSC topology because the two moderate voltages instead of the power rail are fed to the last stage 2:1 SC unit and reduce the voltage swing. The bottom-plate swapping prototype further reduces the parasitic loss at high conversion ratios. To handle a large number of conversion ratios in closed-loop regulation, the ASSC converter uses the fast optimum ratio searching (FORS) technique, which evaluates the transient voltage drop to quickly search for target ratios and reduce the transient recovery time. A three-stage ASSC converter achieving 187 conversion ratios is fully integrated in the test chip, which is fabricated in 0.25-μm CMOS process with an active area of 7.14 mm2. Furthermore, 2389 conversion ratios can be derived in theory for a four-stage ASSC converter. The proposed reconfigurable SC converter provides an output voltage range of 0.4 to 2.8 V under no load conditions, and greater than 80% power efficiency at an output voltage level of 0.9 to 1.5 V over a load range of 3 to 9.5 mA. Due to the FORS technique, the measured transient recovery time is reduced from 7 to 1.5 μs in case of load current step of 7 mA.

Original languageEnglish
Article number8590765
Pages (from-to)9146-9157
Number of pages12
JournalIEEE Transactions on Power Electronics
Volume34
Issue number9
DOIs
StatePublished - Sep 2019

Keywords

  • Asymmetrical shunt switched-capacitor (ASSC) converter
  • DC-DC converter
  • fast optimum ratio searching (FORS) scheme
  • fine-grained voltage conversion ratios (VCRs)
  • fully integrated power management

Fingerprint

Dive into the research topics of 'A Fully Integrated Asymmetrical Shunt Switched-Capacitor DC-DC Converter with Fast Optimum Ratio Searching Scheme for Load Transient Enhancement'. Together they form a unique fingerprint.

Cite this