Abstract
A solid-ankle cushioned heel (SACH) foot is a non-joint foot without natural ankle function. Trans-tibial amputees may occur toe scuffing in the late swing phase due to a lack of active dorsiflexion. To address this problem, clinical guidelines suggests shortening the pylon to produce a smooth gait. However, this causes a leg length discrepancy, induces asymmetry in the hip joint, and causes an overload of L5/S1 joint force. Therefore, this study aimed to investigate the influence of different prosthesis pylons on the hip joint and L5/S1 joint forces.Ten subjects were recruited using leg length for normalisation. Four different pylon reductions (0%, 1%, 2%, and 3%) were used for gait analysis. A Vicon system and force plates were used to collect kinematic data and ground reaction force, respectively. The software package MATLAB was used to create a mathematical model for evaluating the symmetry and force of the hip joint and the low back force of the L5/S1 joint.The model was validated by the correlation coefficient (CC=0.947) and root mean square (RMS=0.028 BW). The model estimated that the 1% group had a symmetrical hip joint force and a lower L5/S1 joint force in the vertical direction. This study indicates that a 1% pylon shortening on a SACH prosthesis is appropriate for a trans-tibial amputee.
Original language | English |
---|---|
Pages (from-to) | 545-548 |
Number of pages | 4 |
Journal | Gait and Posture |
Volume | 40 |
Issue number | 4 |
DOIs | |
State | Published - 2014 |
Keywords
- Gait analysis
- Low back force
- Mathematic model
- SACH foot
- Trans-tibial amputee